Welcome to Seiralab Inc. Committed to Care.

Defibrillator With Paddles and Monitor

Cardiac Monitor Defibrillator

The Cardiac Monitor Defibrillator’s integrated Automated External Defibrillator (AED) and Pulse Oximetry Module offer excellent value for a compact and robust unit.

Description

The Cardiac Monitor Defibrillator’s integrated Automated External Defibrillator (AED) and Pulse Oximetry Module offer excellent value for a compact and robust unit.

Specifications
Screen Type: 7-inch High-resolution display
Waveform: Biphasic
Charge Time: Less than 7 seconds
The Cardiac Monitor defibrillation device can meet your clinical needs, from Basic Life Support (BLS) to Advanced Cardiac Life Support (ACLS).

Display
Screen Type: High-resolution display
Screen Size: 7 inches(17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection, and Limits Delivered Energy.

Defibrillator
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new, fully charged battery.
Energy Display: The monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts.
Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5-lead ECG cable, paddles.
Lead Selection: Displayed on the monitor, paddles I, II, III, AVR, AVL, AVF, V.
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.
Heart Rate: 20-300BPM.
Heart Rate Alarm: On/Off displayed on monitor, user-selectable.
Smart Alarms: Beeper/voice prompts indicate a shockable rhythm.

Battery
Type: Rechargeable, Ni-MH battery, 12V.
Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will affect operating time with different functions.

SpO2 Module
Measurement Range: 30~100%, ±2% between 80%~90%, others ±5%
Alarm Range: The user sets a high limit and a low limit.
Alarm Accuracy: ±10% within setting values.
Alarm Time Accuracy: less than 12 sec.

Recorder
Paper: 50mm thermal.
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.
Printing Method: High-resolution, thermal print head.
Print-out Modes: Manual or automatic, user-configurable.
On/Off Control: Front panel and paddle.
Automatic Function: 9-seconds recording initiated by alarm activation, defibrillator charge, or defibrillator discharge.

AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.
Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV, ventricular tachycardia with rates >=140bpm, and QRS complex wave duration >=140ms.
Charge Control: Control on the device’s front panel; press the key on the paddle.
Prompts: Voice and visual prompts.

Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. The ”SYNC” message is displayed on the monitor.

Reviews

There are no reviews yet.

Be the first to review “Defibrillator With Paddles and Monitor”

Your email address will not be published. Required fields are marked *